Typical Physical Characteristics
Thermia B |
|
|
|
|
||
|
|
|
|
|
||
Density at 15 °C |
|
kg/m3 |
ISO 12185 |
868 |
||
|
|
|
|
|
||
Flash Point PMCC |
|
°C |
ISO 2719 |
210 |
||
|
|
|
|
|
||
Flash Point COC |
|
°C |
ISO 2592 |
220 |
||
|
|
|
|
|
||
Fire Point COC |
|
°C |
ISO 2592 |
255 |
||
|
|
|
|
|
||
Pour Point |
|
°C |
ISO 3016 |
-12 |
||
|
|
|
|
|
||
Kinematic Viscosity |
|
|
ISO 3104 |
|
||
|
|
at 0 °C |
|
mm2/s |
|
230 |
|
|
at 40 °C |
|
mm2/s |
|
25 |
|
|
at 100 °C |
|
mm2/s |
|
4.7 |
|
|
at 200 °C |
|
mm2/s |
|
1.2 |
Initial Boiling Point |
|
°C |
ASTM D 2887 |
355 |
||
|
|
|
|
|
||
Autoignition Temperature |
|
°C |
DIN 51794 |
360 |
||
|
|
|
|
|
||
Neutralisation Value |
mgKOH/g |
ASTM D974 |
< 0.05 |
|||
Ash (Oxid) |
|
%m/m |
ISO 6245 |
< 0.01 |
||
|
|
|
|
|
||
Carbon Residue (Conradson) |
|
%m/m |
ISO 10370 |
0.02 |
||
|
|
|
|
|
||
Copper Corrosion (3h/100°C) |
|
|
ISO 2160 |
class 1 |
||
|
|
|
|
|||
Coefficient of Thermal Expansion |
1/°C |
|
0.0008 |
Typical Design Data
Temperature |
°C |
0 |
20 |
40 |
100 |
150 |
200 |
250 |
300 |
340 |
Density |
kg/m3 |
876 |
863 |
850 |
811 |
778 |
746 |
713 |
681 |
655 |
Specific Heat Capacity |
kJ/kg*K |
1.809 |
1.882 |
1.954 |
2.173 |
2.355 |
2.538 |
2.72 |
2.902 |
3.048 |
Thermal Conductivity |
W/m*K |
0.136 |
0.134 |
0.133 |
0.128 |
0.125 |
0.121 |
0.118 |
0.114 |
0.111 |
Prandtl No. |
|
3375 |
919 |
375 |
69 |
32 |
20 |
14 |
11 |
9 |
Specifications and Approvals
- Classified as ISO 6743-12 Family Q
- Meets typically DIN 51522 requirements
Applications
- Enclosed circulated heat transfer systems for industrial applications such as process industry, chemical plants, textile producers etc. and in household equipment such as oil filled radiators.
- Thermia B can be used in high temperature continuous heat transfer equipment with the following application limits:
Thermia B |
|
|
|
Max. film temperature |
340°C |
|
|
Max. bulk temperature |
320°C |
|
|