Typical Physical Characteristics

Thermia B

 

 

 

 

 

 

 

 

 

Density  at  15  °C

 

kg/m3

ISO  12185

868

 

 

 

 

 

Flash  Point  PMCC

 

°C

ISO  2719

210

 

 

 

 

 

Flash  Point  COC

 

°C

ISO  2592

220

 

 

 

 

 

Fire  Point  COC

 

°C

ISO  2592

255

 

 

 

 

 

Pour  Point

 

°C

ISO  3016

-12

 

 

 

 

 

Kinematic  Viscosity

 

 

ISO  3104

 

 

 

at  0  °C

 

mm2/s

 

230

 

 

at  40  °C

 

mm2/s

 

25

 

 

at  100  °C

 

mm2/s

 

4.7

 

 

at  200  °C

 

mm2/s

 

1.2

Initial  Boiling  Point

 

°C

ASTM  D 2887

355

 

 

 

 

 

Autoignition  Temperature

 

°C

DIN 51794

360

 

 

 

 

 

Neutralisation  Value

mgKOH/g

ASTM  D974

<  0.05

Ash  (Oxid)

 

%m/m

ISO  6245

<  0.01

 

 

 

 

 

Carbon  Residue  (Conradson)

 

%m/m

ISO  10370

0.02

 

 

 

 

 

Copper  Corrosion  (3h/100°C)

 

 

ISO  2160

class  1

 

 

 

 

Coefficient  of  Thermal  Expansion

1/°C

 

0.0008

 

Typical Design Data

Temperature

°C

0

20

40

100

150

200

250

300

340

Density

kg/m3

876

863

850

811

778

746

713

681

655

Specific  Heat  Capacity

kJ/kg*K

1.809

1.882

1.954

2.173

2.355

2.538

2.72

2.902

3.048

Thermal  Conductivity

W/m*K

0.136

0.134

0.133

0.128

0.125

0.121

0.118

0.114

0.111

Prandtl  No.

 

3375

919

375

69

32

20

14

11

9

Specifications and Approvals

  • Classified as ISO 6743-12 Family Q
  • Meets typically DIN 51522 requirements

Applications

  • Enclosed circulated heat transfer systems for industrial applications such as process industry, chemical plants, textile producers etc. and in household equipment such as oil filled radiators.
  • Thermia B can be used in high temperature continuous heat transfer equipment with the following application limits:

Thermia  B

 

 

 

Max.  film  temperature

340°C

 

 

Max.  bulk  temperature

320°C

 

 

Get it now